Project

General

Profile

Actions

Bug #890

closed

Every time Print is called, a portion of the top line of the screen is cleared

Added by Brian Flanagan over 2 years ago. Updated over 2 years ago.

Status:
Closed
Priority:
High
Assignee:
-
Target version:
Start date:
02/10/2022
Due date:
% Done:

0%

Estimated time:
1:00 h
Affected version:

Description

The current location of the text cursor is ignored. It SHOULD be clearing the area that is just about to be printed
The area cleared always starts at 0,0, and is the same length as whatever was just printed.

Actions #1

Updated by David Baldwin over 2 years ago

  • Status changed from New to Resolved

Resolved by reverting to pre-rewrite of printLine function.

Actions #2

Updated by Brian Flanagan over 2 years ago

  • Status changed from Resolved to Closed

Verified. It's working now! ...in the latest B12 version.

Actions #3

Updated by Francois Lionet over 2 years ago

Fixed for good: there was a remaining ClearRect in the printLine function.

Actions